Yes, that should be enough voltage to make it crank. To double check your starter, pull the starter and bench test it with a set of jumper cables, taking the solenoid completely out of the equation. You could do this with the starter still installed if you have access to it. If you leave it installed, be sure to connect the negative jumper cable as well, connecting it to the starter housing. The key does not need to be on to do this.